Part Number Hot Search : 
IRFU9020 1N2980D 10500 2702B P80NE03 A224M B4226 HT82K628
Product Description
Full Text Search
 

To Download D2FW-G283M Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 d 2 f w - g d2fw-g m4 mounting seal ed basic switch easy to mount with one single screw. a sealed switch ideal for use in adverse environment conditions single-point mounting with an m4 screw. incorporates a fixed leaf lever for tough environments. molded lead wires are in stalled using lead-free connections for environmental conservation. rohs compliant model number legend list of models contact form contact specifications * please refer to " using micro loads " in " precautions " for more information on the minimum applicable load. ratings note. the above rating values apply under the following test conditions. (1) ambient temperature: 20 2c (2) ambient humidity: 65 5% (3) operating frequency: 20 operations/min ratings 1 a 0.1 a actuator contact form leaf lever spdt d2fw-g271m d2fw-g071m spst-nc d2fw-g272m d2fw-g072m spst-no d2fw-g273m d2fw-g073m long leaf lever spdt d2fw-g281m d2fw-g081m spst-nc d2fw-g282m d2fw-g082m spst-no D2FW-G283M d2fw-g083m d2fw-g @@@ m 1. ratings 2 : 30 vdc 1a 0 : 30 vdc 0.1a 2. levers 7 : leaf lever 8 : long leaf lever 3. contact form 1 : spdt 2 : spst-nc 3 : spst-no 1 23 spdt spst-nc spst-no com (black) no (blue) nc (red) com (black) nc (red) the color in parentheses indicates the color of the lead wire. com (black) no (blue) item model d2fw-g2 models d2fw-g0 models contact specification crossbar material silver alloy gold alloy gap (standard value) 0.25 mm minimum applicable load (reference value) * 5 vdc 100 ma 5 vdc 1 ma model d2fw-g2 models d2fw-g0 models rated voltage resistive load 30 vdc 1 a 0.1 a
2 d2fw-g m4 mounting sealed basic switch d 2 f w - g dimensions (unit: mm) /operating characteristics the @ is replaced with the code for the ratings and the contact forms. see the " list of models " for available combinations of shapes. note1. unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. note2. the operating characteristics are for operation in the a direction ( ). characteristics note. the data given above are initial values. *1. the values are at free position and total travel position values for pin plunger, and total travel position value for lever. close or open circuit of the contact is 1ms max. *2. for testing conditions, consult your omron sales representative. item model d2fw-g2 models d2fw-g0 models permissible operating speed 1mm to 500mm/s permissible operating frequency mechanical 120 operations/min electrical 30 operations/min insulation resistance 100 m min. (at 500 vdc with insulation tester) contact resistance (initial value) 100 m max. 150 m max. dielectric strength between terminals of the same polarity 600 vac 50/60 hz for 1 min between current-carrying metal parts and ground 1,500 vac 50/60 hz for 1 min between each terminal and non-current-carrying metal parts 1,500 vac 50/60 hz for 1 min vibration resistance * 1 malfunction 10 to 55 hz, 1.5 mm double amplitude shock resistance durability 1,000 m/s 2 {approx. 100g} max. malfunction * 1 300 m/s 2 {approx. 30g} max. durability * 2 mechanical 300,000 operations min. (60 operations/min) electrical 30,000 operations min. (20 operations/min) 100,000 operations min. (20 operations/min) degree of protection iec ip67 ambient operating temperature -40c to + 85c (at ambient humidity 60% max.) (with no icing or condensation) ambient operating humidity 95% max. (for + 5c to + 35c) weight approx. 10.4 g (for spdt model) mounting holes (unit: mm) 16 m4 tap 4 + 0.1 dia. holes 0 (depth: 2mm min.) d2fw >+ g >& 22.8 >' t0.2 stainless-steel lever 8 22 5 16 0.15 15.3 5 >& 5 >' 13.5 300 10 23.5 4.7 4.2 + 0.2 dia. 0 4 + 0.2 dia. 0 r3.5 4 0 dia.  0.15 no avs0.5 (blue) nc avs0.5 (red) com avs0.5 (black) lead wire a operating position free position leaf lever d2fw-g # 7 # m operating characteristics type model leaf lever d2fw-g # 7 # m operating force of max. releasing force rf min. 2.45n {250 gf} 0.29n {30 gf} overtravel ot min. movement differential md max. 1.0 mm 1.0 mm free position fp max. operating position op total travel position ttp 15.5 mm 11.5 2 mm 6.5 mm (reference value) long leaf lever d2fw-g # 8 # m operating characteristics type model long leaf lever d2fw-g # 8 # m operating force of max. releasing force rf min. 2.94n {300 gf} 0.59n {60 gf} overtravel ot min. movement differential md max. 1.0 mm 1.0 mm free position fp max. operating position op total travel position ttp 19 mm 12 2 mm 8.5 mm (reference value) d2fw >+ g >& 19 >' t0.2 stainless-steel lever 8 22 5 16 0.15 15.3 >& 5 >' 5 operating position free position 13.5 300 10 23.5 4.7 no avs0.5 (blue) nc avs0.5 (red) r3.5 com avs0.5 (black) lead wire a 4.2 + 0.2 dia. 0 4 + 0.2 dia. 0 4 0 dia.  0.15
3 d2fw-g m4 mounting sealed basic switch d 2 f w - g precautions please refer to "basic switches comm on precautions" for correct use. use the switch within the specified voltage rating. using the switch outside of the rated values will not only shorten its durability but may cause heat generation or fire damage. when turning the power on or off, use the rated voltage and current. degree of protection do not use the switch underwater. the switch was tested and found to meet the conditions necessary to meet the following standards. the test checks for water intrusion after immersion for a specified time period, not for switching operation underwater. jis c0920: degrees of protection provided by enclosures of electrical apparatus (ip code) iec 60529: degrees of protection provided by enclosures (ip code) degree of protection: ip67 (check water intrusion after immersion for 30 min. submerged 1m underwater) protection against chemicals prevent the switch from coming into contact with oil or chemicals. otherwise, damage to or deterioration of switch materials may result. mounting ? turn off the power supply before mounting or removing the switch, wiring, or performing maintenance or inspection. failure to do so may result in electric shock or burning. ? use m4 mounting screws with plane washers or spring washers to securely mount the switch. tighten the screws to a torque of 1.18 to 1.47nm {12 to 15 kgfcm}. switch mounting when mounting the switch, do not apply force to the actuator in any direction other than its operating direction. operation make sure that the switching object is perfectly separated from the actuator when it is at the free position and the actuator is pressed appropriately by the switching object when the switch is operated. the switching object must not move beyond its total travel position, otherwise the switch may be damaged. install the switching object so that its moving direction is the same as that of the actuator. using micro loads ? even when using micro load models within the operating range shown below, if inrush/surge current occurs, it may increase the contact wear and so decrease durability. therefore, insert a contact protection circuit where necessary. ? the minimum applicable load is the n-level reference value. this value indicates the malfunction reference level for the reliability level of 60% ( 60 ). (jis c5003) the equation, 60 =0.510 -6 /operations, indicates that the estimated malfunction rate is less than operations with a reliability level of 60%. cautions correct use 1 2,000,000 30 24 12 5 0 1 10 100 1,000 current (ma) 0.1 operating range for general-load models d2fw-g2 # operating range for micro load models d2fw-g0 # 16.6 ma 0.16 ma 100 ma 1ma voltage (v)
4 d2fw-g m4 mounting sealed basic switch d 2 f w - g ? application examples provided in this document are for reference only. in actual applications, confirm equipment functions and safety before using the product. ? consult your omron representative before using the product under conditions which are not described in the manual or applying t he product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other sys tems or equipment that may have a serious influence on lives and property if used improperly. make sure that the ratings and performance characteristics of the product p rovide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. omron corporation electronic and mechanical components company contact: www.omron.com/ecb cat. no. b104-e1-03 0812(0207)(o) note: do not use this document to operate the unit.


▲Up To Search▲   

 
Price & Availability of D2FW-G283M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X